Range of productAltivar Machine ATV340
Product or component typeVariable speed drive
Product specific applicationMachine
variantStandard version
mounting modeCabinet mount
Communication port protocolSercos
Modbus serial
Network number of phases3 phases
Supply frequency50...60 Hz +/- 5 %
[Us] rated supply voltage380...480 V - 15...10 %
Nominal output current2.2 A
Motor power kW1.1 kW for normal duty
0.75 kW for heavy duty
Motor power hp1.5 hp for normal duty
1 hp for heavy duty
EMC filterClass C3 EMC filter integrated
IP degree of protectionIP20
Complementary
Discrete input number5
Discrete input typePTI safe torque off: 0…30 kHz, 24 V DC (30 V)
DI1...DI5 discrete input, 24 V DC (30 V), impedance: 3.5 kOhm
number of preset speeds16 preset speeds
Discrete output number2.0
Discrete output typeProgrammable output DQ1, DQ2 30 V DC 100 mA
Analogue input number2
Analogue input typeAI1 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI2 software-configurable voltage: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number1
Analogue output typeSoftware-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1: 0...20 mA impedance 500 Ohm, resolution 10 bits
Relay output number2
Output voltage<= power supply voltage
Relay output typeRelay outputs R1A
Relay outputs R1C electrical durability 100000 cycles
Relay outputs R2A
Relay outputs R2C electrical durability 100000 cycles
Maximum switching currentRelay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching currentRelay output R1B: 5 mA at 24 V DC
Relay output R2C: 5 mA at 24 V DC
Physical interface2-wire RS 485
Connector type3 RJ45
Method of accessSlave Modbus RTU
Transmission rate4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frameRTU
Number of addresses1…247
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
4 quadrant operation possibleTrue
Asynchronous motor control profileConstant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profilePermanent magnet motor
Reluctance motor
Pollution degree2 conforming to IEC 61800-5-1
Maximum output frequency0.599 kHz
Acceleration and deceleration rampsS, U or customized
Linear adjustable separately from 0.01...9999 s
Motor slip compensationCan be suppressed
Not available in permanent magnet motor law
Automatic whatever the load
Adjustable
Switching frequency2...16 kHz adjustable
14...16 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedTrue
Line current2.6 A at 380 V (normal duty)
2.1 A at 480 V (normal duty)
3.4 A at 380 V (heavy duty)
2.6 A at 480 V (heavy duty)
Line current2.6 A at 480 V without line choke (heavy duty)
2.6 A at 380 V with external line choke (normal duty)
2.1 A at 480 V with external line choke (normal duty)
1.9 A at 380 V with external line choke (heavy duty)
1.6 A at 480 V with external line choke (heavy duty)
3.4 A at 380 V without line choke (heavy duty)
Maximum input current3.4 A
Maximum output voltage480 V
Apparent power2.2 kVA at 480 V (normal duty)
2.2 kVA at 480 V (heavy duty)
Maximum transient current3.1 A during 60 s (normal duty)
3.3 A during 60 s (heavy duty)
3.8 A during 2 s (normal duty)
4 A during 2 s (heavy duty)
Electrical connectionScrew terminal, clamping capacity: 1.5...4 mm² for line side
Screw terminal, clamping capacity: 4...6 mm² for DC bus
Screw terminal, clamping capacity: 1.5...4 mm² for motor
Screw terminal, clamping capacity: 0.2...2.5 mm² for control
Prospective line Isc5 kA
Base load current at high overload2.2 A
Base load current at low overload2.8 A
Power dissipation in WNatural convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty)
Forced convection: 28 W at 380 V, switching frequency 4 kHz (heavy duty)
Natural convection: 33 W at 380 V, switching frequency 4 kHz (normal duty)
Forced convection: 33 W at 380 V, switching frequency 4 kHz (normal duty)
Electrical connectionLine side: screw terminal 1.5...4 mm²/AWG 14...AWG 12
DC bus: screw terminal 4...6 mm²/AWG 12...AWG 10
Motor: screw terminal 1.5...4 mm²/AWG 14...AWG 12
Control: screw terminal 0.2...2.5 mm²/AWG 24...AWG 12
With safety function Safely Limited Speed (SLS)True
With safety function Safe brake management (SBC/SBT)True
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)True
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection: motor
Safe torque off: motor
Motor phase loss: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent: drive
Output overcurrent between motor phase and earth: drive
Output overcurrent between motor phases: drive
Short-circuit between motor phase and earth: drive
Short-circuit between motor phases: drive
Motor phase loss: drive
DC Bus overvoltage: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Input supply loss: drive
Exceeding limit speed: drive
Break on the control circuit: drive
Width85.0 mm
Height270.0 mm
Depth232.5 mm
Net weight1.7 kg
Continuous output current2.2 A at 4 kHz for heavy duty
2.8 A at 4 kHz for normal duty
Environment
Operating altitude<= 3000 m with current derating above 1000m
Operating positionVertical +/- 10 degree
Product certificationsUL
CSA
TÜV
EAC
CTick
markingCE
StandardsIEC 61800-3
IEC 61800-5-1
IEC 60721-3
IEC 61508
IEC 13849-1
UL 618000-5-1
UL 508C
Assembly styleWith heat sink
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)70 m/s² at 22 ms
Maximum acceleration under vibrational stress (during operation)5 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...9 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air18.0 m3/h
Type of coolingForced convection
Overvoltage categoryClass III
Regulation loopAdjustable PID regulator
Noise level52.7 dB
Pollution degree2
Ambient air transport temperature-40…70 °C
Ambient air temperature for operation-15…50 °C without derating (vertical position)
50…60 °C with derating factor (vertical position)
Ambient air temperature for storage-25…70 °C
IsolationBetween power and control terminals
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.7 cm
Package 1 Width37.5 cm
Package 1 Length31.5 cm
Package 1 Weight2.485 kg



Schneider Electric ATV340U07N4S Variable speed drive, Altivar Machine ATV340, 0.75 kW, 400 V, 3 phases, Sercos

Schneider Electric ATV340U07N4S Variable speed drive, Altivar Machine ATV340, 0.75 kW, 400 V, 3 phases, Sercos

Related Products

WRITE TO US

ava.wong@hkxytech.com

MOBILE PHONE

+86 15602323637

CONTACT ADDRESS

7-A16,Caishen Commercial Plaza, Hankou Railway Station,Wuhan, China

HONGKONG XIEYUAN TECH CO., LIMITED is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.