Schneider Electric ATV630U07N4Z variable speed drive, Altivar Process ATV600, ATV630, cabinet Integration, IP20, 0.75kW, 380 to 480V


Range of productAltivar Process ATV600
Product or component typeVariable speed drive
Product specific applicationProcess and utilities
Device short nameATV630
variantStandard version
Product destinationAsynchronous motors
Synchronous motors
EMC filterIntegrated with 10 m conforming to IEC 61800-3 category C2
Integrated with 50 m conforming to IEC 61800-3 category C3
With EMC plate option
IP degree of protectionIP20 conforming to IEC 61800-5-1
IP20 conforming to IEC 60529
[Us] rated supply voltage380...480 V
Type of coolingForced convection
Supply frequency50...60 Hz - 5...5 %
[Us] rated supply voltage380...480 V - 15...10 %
Motor power kW0.75 kW (normal duty)
0.37 kW (heavy duty)
Motor power hp1 hp normal duty
0.5 hp heavy duty
Line current1.5 A at 380 V (normal duty)
1.3 A at 480 V (normal duty)
0.9 A at 380 V (heavy duty)
0.8 A at 480 V (heavy duty)
Prospective line Isc50 kA
Apparent power1.1 kVA at 480 V (normal duty)
0.7 kVA at 480 V (heavy duty)
Continuous output current2.2 A at 4 kHz for normal duty
1.5 A at 4 kHz for heavy duty
Asynchronous motor control profileConstant torque standard
Variable torque standard
Optimized torque mode
Synchronous motor control profilePermanent magnet motor
Synchronous reluctance motor
Speed drive output frequency0.1…500 Hz
Nominal switching frequency4 kHz
Switching frequency2...12 kHz adjustable
4...12 kHz with derating factor
Safety functionSTO (safe torque off) SIL 3
Discrete input logic16 preset speeds
Communication port protocolModbus TCP
Ethernet
Modbus serial
Option cardSlot A: communication module, Profibus DP V1
Slot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Complementary
mounting modeCabinet mount
Maximum transient current2.4 A during 60 s (normal duty)
2.3 A during 60 s (heavy duty)
Network number of phases3 phases
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage<= power supply voltage
Permissible temporary current boost1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
Motor slip compensationNot available in permanent magnet motor law
Can be suppressed
Automatic whatever the load
Adjustable
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Physical interfaceEthernet
2-wire RS 485
Braking to standstillBy DC injection
Protection typeThermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Transmission rate10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolutionDisplay unit: 0.1 Hz
Analog input: 0.012/50 Hz
Transmission frameRTU
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10
Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
Method of accessSlave Modbus TCP
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Width130 mm
Height285 mm
Depth196 mm
Net weight3.7 kg
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibilityDI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Sampling duration2 ms +/- 0.5 ms (DI1...DI4) - discrete input
5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
IsolationBetween power and control terminals
Maximum output frequency500 kHz
Maximum input current1.5 A
Variable speed drive application selectionBuilding - HVAC compressor centrifugal
Food and beverage processing other application
Mining mineral and metal fan
Mining mineral and metal pump
Oil and gas fan
Water and waste water other application
Building - HVAC screw compressor
Food and beverage processing pump
Food and beverage processing fan
Food and beverage processing atomization
Oil and gas electro submersible pump (ESP)
Oil and gas water injection pump
Oil and gas jet fuel pump
Oil and gas compressor for refinery
Water and waste water centrifuge pump
Water and waste water positive displacement pump
Water and waste water electro submersible pump (ESP)
Water and waste water screw pump
Water and waste water lobe compressor
Water and waste water screw compressor
Water and waste water compressor centrifugal
Water and waste water fan
Water and waste water conveyor
Water and waste water mixer
Motor power range AC-30.55…1 kW at 380…440 V 3 phases
0.55…1 kW at 480…500 V 3 phases
Quantity per set1
enclosure mountingWith heat sink
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level54.5 dB conforming to 86/188/EEC
Power dissipation in WNatural convection: 26 W at 380 V, switching frequency 4 kHz
Forced convection: 21 W at 380 V, switching frequency 4 kHz
Volume of cooling air38 m3/h
Operating positionVertical +/- 10 degree
Maximum THDI<48 % full load conforming to IEC 61000-3-12
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating)
50…60 °C (with derating factor)
Ambient air temperature for storage-40…70 °C
Operating altitude<= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m
Product certificationsTÜV
ATEX zone 2/22
CSA
DNV-GL
UL
ATEX INERIS
markingCE
StandardsUL 508C
IEC 61800-3
IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
Assembly styleWith heat sink
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Noise level54.5 dB
Pollution degree2
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height31.800 cm
Package 1 Width19.000 cm
Package 1 Length40.000 cm
Package 1 Weight4.704 kg
Unit Type of Package 2P06
Number of Units in Package 26
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight41.200 kg



Schneider Electric ATV630U07N4Z variable speed drive, Altivar Process ATV600, ATV630, cabinet Integration, IP20, 0.75kW, 380 to 480V

Schneider Electric ATV630U07N4Z variable speed drive, Altivar Process ATV600, ATV630, cabinet Integration, IP20, 0.75kW, 380 to 480V

Related Products

WRITE TO US

ava.wong@hkxytech.com

MOBILE PHONE

+86 15602323637

CONTACT ADDRESS

7-A16,Caishen Commercial Plaza, Hankou Railway Station,Wuhan, China

HONGKONG XIEYUAN TECH CO., LIMITED is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.