variable speed drive, Altivar Process ATV600, ATV650, 75kW, 100hp, 380 to 480V, IP55 ATV650D75N4

variable speed drive, Altivar Process ATV600, ATV650, 75kW, 100hp, 380 to 480V, IP55 ATV650D75N4

Model: ATV650D75N4

Supplier: Schneider Electric

Categories: Variable Speed Drives and Soft Starters

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 75kW / 100hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 55kW / 75hp for applications requiring significant overload (up to 150%). It weighs 87kg and its dimensions are, 345mm wide, 1250mm high, 375mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.


Main
Range of productAltivar Process ATV600
Product or component typeVariable speed drive
Product specific applicationProcess and utilities
Device short nameATV650
VariantStandard version
Product destinationAsynchronous motors
Synchronous motors
EMC filterIntegrated with 150 m conforming to IEC 61800-3 category C3
IP degree of protectionIP55 conforming to IEC 60529
IP55 conforming to IEC 61800-5-1
[Us] rated supply voltage380...480 V
Type of coolingForced convection
Supply frequency50...60 Hz - 5...5 %
[Us] rated supply voltage380...480 V - 15...10 %
Motor power kW55.0 kW (heavy duty)
75.0 kW (normal duty)
Motor power hp60 hp heavy duty
100 hp normal duty
Line current84.2 A at 480 V (normal duty)
81.4 A at 380 V (heavy duty)
71.8 A at 480 V (heavy duty)
131.3 A at 380 V (normal duty)
Prospective line Isc50 kA
Apparent power59.7 kVA at 480 V (heavy duty)
93.7 kVA at 480 V (normal duty)
Continuous output current87 A for heavy duty
145 A at 2.5 kHz for normal duty
Asynchronous motor control profileConstant torque standard
Optimized torque mode
Optimized torque mode
Synchronous motor control profileSynchronous reluctance motor
Permanent magnet motor
Speed drive output frequency0.1…500 Hz
Nominal switching frequency2.5 kHz
Switching frequency2...8 kHz adjustable
2.5...8 kHz with derating factor
Safety functionSTO (safe torque off) SIL 3
Discrete input logic16 preset speeds
Communication port protocolModbus TCP
Ethernet
Modbus TCP
Option cardSlot A: communication module, PROFINET
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Slot A: communication module, Profibus DP V1
Complementary
mounting modeWall mount
Maximum transient current132 A during 60 s (heavy duty)
159.5 A during 60 s (normal duty)
Network number of phases3 phases
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage<= power supply voltage
Permissible temporary current boost1.5 x In during 60 s (heavy duty)
1.1 x In during 60 s (normal duty)
Motor slip compensationNot available in permanent magnet motor law
Adjustable
Can be suppressed
Adjustable
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Physical interfaceEthernet
2-wire RS 485
Braking to standstillBy DC injection
Protection typeSafe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Thermal protection: motor
Transmission rate10, 100 Mbits
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolutionAnalog input: 0.012/50 Hz
Display unit: 0.1 Hz
Transmission frameRTU
Electrical connectionMotor: screw terminal 70...120 mm²/AWG 1/0...250 kcmil
Line side: screw terminal 70...95 mm²/AWG 1...250 kcmil
Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16
Connector typeRJ45 (on the remote graphic terminal) for Modbus serial
RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
Method of accessSlave Modbus TCP
SupplyInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Local signalling3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
3 LEDs for local diagnostic
Width345 mm
Height1250 mm
Depth375 mm
Net weight87 kg
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibilityDI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
DI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable current DQ-, DQ+: 30 V DC
Software-configurable current DQ-, DQ+: 100 mA
Sampling duration5 ms +/- 1 ms (DI5, DI6) - discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
10 ms +/- 1 ms (AO1) - analog output
2 ms +/- 0.5 ms (DI1...DI4) - discrete input
Accuracy+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
Linearity errorAO1, AO2: +/- 0.2 % for analog output
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
Relay output number3
Relay output typeConfigurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
IsolationBetween power and control terminals
Maximum output frequency500 kHz
Maximum input current131.3 A
Variable speed drive application selectionBuilding - HVAC compressor centrifugal
Motor power range AC-355…100 kW at 380…440 V 3 phases
Quantity per set1
enclosure mountingWall mounted
Environment
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level69.9 dB conforming to 86/188/EEC
Operating positionVertical +/- 10 degree
Maximum THDI<48 % from 80...100 % of load conforming to IEC 61000-3-12
Electromagnetic compatibilityRadiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation40…50 °C (with derating factor)
-15…40 °C (without derating)
Ambient air temperature for storage-40…70 °C
Operating altitude1000...4800 m with current derating 1 % per 100 m
<= 1000 m without derating
product certificationsUL
DNV-GL
CSA
ABS
Bureau Veritas
TÜV
ATEX INERIS
markingCE
StandardsIEC 61800-3
IEC 61800-3 environment 1 category C2
EN/IEC 61800-3 environment 2 category C3
IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
UL 508C
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Noise level69.9 dB
Pollution degree3
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height70.0 cm
Package 1 Width50.0 cm
Package 1 Length145.0 cm
Package 1 Weight95.0 kg



variable speed drive, Altivar Process ATV600, ATV650, 75kW, 100hp, 380 to 480V, IP55 ATV650D75N4

variable speed drive, Altivar Process ATV600, ATV650, 75kW, 100hp, 380 to 480V, IP55 ATV650D75N4

Related Products

WRITE TO US

ava.wong@hkxytech.com

MOBILE PHONE

+86 15602323637

CONTACT ADDRESS

7-A16,Caishen Commercial Plaza, Hankou Railway Station,Wuhan, China

HONGKONG XIEYUAN TECH CO., LIMITED is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.